Photo – Electric Switch Relays 

fotoselgoz sfr02

sfr 01 kfr02

 TYPE   SFR 01 / KFR 01 / KFR 01A / KFR 02 / KFR 03 
 ORDER CODE   67015/67003/67010/67110/67210/67310/67410/67500 
 GENERAL SPECIFICATIONS   According to Adjusted level of luminosity relay switch ON and OFF the system after a delay time.Led displays that shows Supply, Relay position and operation Photo electric sensor that measures the ambient luminosity is in water – tight housing.Photo Electric Switchs are switch ON the system when the envoirement luminosity is decreased, switch OFF the system when it is increased. KFR and SFR has a system that is adjustable between 1 – 10 lux and  1..3 Lux. When the enviromental luminosity is decreased below. The adjusted value “opr.” led lights and after a delay time Switch – OFF the system. The same happens as opposite and Switch – ON the system. KFR 02, KFR 03, SFR 02 and SFR 03 have manual operation mode. Delay time is for to prevent system to be affected by sudden light sources like lightning or car headlights. This delay is aprox. 35 seconds.According to Adjusted level of luminosity relay switch ON and OFF the system after a delay time. Led displays that shows Supply, Relay position and operation Photo electric sensor that measures the ambient luminosity is in water – tight housing. Photo Electric Switchs are switch ON the system when the envoirement luminosity is decreased, switch OFF the system when it is increased. KFR and SFR has a system that is adjustable between 1 – 10 lux and  1..3 Lux. When the enviromental luminosity is decreased below. The adjusted value “opr.” led lights and after a delay time Switch – OFF the system. The same happens as opposite and Switch – ON the system. KFR 02, KFR 03, SFR 02 and SFR 03 have manual operation mode. Delay time is for to prevent system to be affected by sudden light sources like lightning or car headlights. This delay is aprox. 35 seconds. 
 SETTING ACCURACY   %2 of Whole Scale 
 OUTPUT CONTACT   SPDT Relay (inversor) 10A / 250 Vac (Resistive Load) 
 SUPPLY VOLTAGE   220 Vac ± %20, 50 / 60 Hz 
 POWER CONSUMPTION   < 1VA 
 OPERATING TEMPERATURE   -5°C…+55 °C 
 ELECTRICAL LIFE   100.000 ON /OFF (Resistive Load) 
 MOUNTING TYPE   SSR02, SSR03, SSR04: For Mounting on DIN Rail or Inside Panel
SSR 02S-11: 11 Pin Socket
SSR 02S-8: 8 Pin Socket 
 PROTECTION CLASS   IP 20

 Order Code   Type   Sensitivity Range   Output   Control   Protection   Electrical Connection   Weight 
 67015  SFR 01   1… 10 Lux  Relay  Automatic   PCB Connector  0,13 kg
 67003  KFR 01A   1… 3 Lux  Relay  Automatic   PCB Connector  0,3 kg
 67010  KFR 01  1… 10 Lux  Relay  Automatic   PCB Connector  0,3 kg
 67110  KFR 02  1… 10 Lux  Relay  Automatic or Manual   Fuse  PCB Connector  0,3 kg
 67210  KFR 03  1… 10 Lux  Triac  Automatic or Manual  Fuse  PCB Connector  0,3 kg
 67500  KFG Photocell Eyes 

Categories: KRK